Sheet 13 / Legacy PLC Recovery

Legacy PLC Recovery & Reverse Engineering

When the programming software is gone, the program is lost or nobody knows how the machine talks, we work it out from the hardware.

Inside the banana dryer control panel we built, programmed and commissioned
FIG. 13Inside the banana dryer control panel we built, programmed and commissioned

Keeping old machines running

A lot of good plant in Far North Queensland runs on controllers that are twenty or thirty years old. The laptop with the software died, the integrator closed down, and the program was never backed up. When it stops, the usual answer is a full rip-out. Often it does not need to be.

We have written our own tools to talk to PLCs without the maker's programming software: Siemens S7-200 SMART over Ethernet and Schneider M221 over Modbus TCP. The S7-200 SMART is a different product from the older S7-200 range, and the M221 is a current controller: the tools are for when the maker's software, the project file or the licence is not to hand. We have also decoded the old Modicon TSX Micro serial link, and the internal RS-485 Modbus link inside a rack UPS.

Where the program can still be read out, with the maker's software if a copy exists, we read it, back it up and document it. Where it cannot, we map what the machine does and write a new program that does the same, then commission it on site. The banana dryer on our Control and automation page is a full control system we built from scratch.

Panel wiring close-up
Panel wiring close-up

Recovery work we do

Program backup and documentation
Where the controller allows it, read the program out and keep a backup, then document the inputs, outputs and logic, so the next person is not starting blind.
Replacement controllers
Swap a failed or obsolete PLC for a current one, with the logic written to match how the machine runs now.
Protocol decoding
Working out how undocumented equipment talks by recording the traffic on its serial or network link, so it can be monitored or controlled from something current.
Monitoring old plant
Small interface boards and computers that pull readings and faults off old RS-485 and Modbus gear and pass them to a dashboard, without touching the control logic.

Questions we get asked

Our PLC is 20 or 30 years old. What are the real options?

There are three. Read the program out if there is any way to reach it. If there is not, record what the machine does on its inputs, outputs and links, and document it. Or fit a current controller with the logic written to match. Which fits depends on the make and model, so send that first.

We have no software and no backup. Can you still change the program?

On a Siemens S7-200 SMART, yes: our own tools compile and download simple programs and read live data. On a Schneider M221 they read live data. If we cannot get into your controller, we replace it with a current one and write the program to match the machine.

My PLC is a different make. Is it worth calling?

Yes. Send the make and model, a photo of the PLC and its label, and any old printout or backup file that came with the machine. If we cannot read it, replacing the controller works on any brand.

What happens after I send the model?

We tell you whether we expect to read the program or whether the controller will need replacing, and what that means for your machine. Work on site starts with a backup of whatever can be read.

Do you answer breakdown calls out of hours?

Yes. If a machine is down, ring 07 4243 3488 at night or on the weekend, not just in trading hours.

Who fits the replacement controller?

We do. The PLC sits on the panel's 24 volt control side, so we swap it, wire it and commission it ourselves, with one person accountable from the backup to the restart.

Is it safe to connect to a running machine?

Reading is safe on most controllers and is where we start. Anything that writes to the PLC is done on site, with a backup taken first, and the machine stopped and isolated whenever the job calls for it.

What if the program is password protected?

Protection usually stops the program being read out. Then we work out what the machine does from its wiring and behaviour, and write a new program for it.

What does it cost?

It depends on the controller and whether the program can be read out. Send the make and model and a photo of the panel and we will price it.

Where we work

Based in Cairns. We travel to the Tablelands, Cape York and across Far North Queensland, and interstate for the right job.

Service area: Cairns, the Tablelands and Cape York. Schematic, not to scale. CAPE YORK TABLELANDS CairnsMareebaAtherton N SCHEMATIC. NOT TO SCALE

Old machine, no software, nobody left who knows it?

Tell us the make and model of the controller and what the machine does. We will tell you whether the program can be read or the controller needs replacing. If the machine is down now, ring us.